Local Authority Building Control (LABC) - Wednesday 8th December 2021 (2/2)

8 December 2021 · Barry Turner - LABC Technical Lead, Counsel to the Inquiry · 2:27:21
▶ Watch on YouTube Open in interactive viewer

Evidence session examining the role of Local Authority Building Control in the approval and oversight of building work at Grenfell Tower.

Key moments

Full transcript

# Transcribed with OpenAI Whisper (medium model)

# Source: Local audio transcription (no YouTube captions available)

00:00:00 Would you ask Mr Turner to come back in please?

00:00:27 Right Mr Turner, ready to carry on. Good, thank you very much. Yes, Ms Grange.

00:00:52 Yes, thank you. I want to ask you some questions now about LABC's relationship with manufacturers,

00:00:58 and in particular with Kingspan. And can we start by looking at your witness statement

00:01:02 please at page 4 paragraph 16. So there you say this, I have limited engagement with product

00:01:15 manufacturers. Such engagement would be responding to specific technical inquiries of a general nature

00:01:21 and not necessarily related to a particular project system approval or registered detail. Whilst I have

00:01:28 had dealings with Kingspan, they have not related to K15 with the exception of an initial phone call

00:01:33 with Andrew Pack in 2008 detailed below. I've had no direct dealings with Celetex. Now when you say

00:01:40 I have limited engagement with product manufacturers, are you there drawing a distinction

00:01:45 between the engagement you had in your role, a senior technical role, and the engagement that

00:01:50 the LABC more generally had? Yes. Right, so do you accept that the LABC itself had quite extensive

00:01:58 engagement with manufacturers? Yes. Yes. Now let's look at Kingspan in particular because what we can

00:02:06 see is that the LABC was collaborating with Kingspan on a number of different projects.

00:02:13 So for example in November 2008 the LABC collaborated with Kingspan to produce a guidance for tapered

00:02:20 roofing. Do you recall that? I do. Let's look at the document LABC 0016947. So this is that technical

00:02:35 guidance note, that LABC technical guidance note for tapered roofing November 08. And we can see

00:02:41 in that top set of boxes that we've got an in conjunction with Kingspan and then we have the

00:02:46 Kingspan logo next door to the LABC logo. Do you see that? I do. And was this a piece of guidance

00:02:53 that you were aware of at the time? Yes. Now at the time that the LABC was in the process of issuing

00:03:01 the 2009 system type approval certificate for K15, on the 6th of April 2009 it received an email

00:03:09 from someone called Christopher Hall, the sales and marketing director of an organization called

00:03:14 Reticell, who was concerned that the LABC was unfairly promoting Kingspan as a manufacturer.

00:03:22 Let's have a look at that email. It's at LABC 308172.

00:03:28 Now this is in the second half of that page. We can see this email from Mr. Hall at Reticell.

00:03:42 It's copied to Paul Everill, the chief exec, and then you are CC. Do you see that?

00:03:49 CC Barry 10, LABC. 6th of April 2009. And he says this, dear Mr. Everill, we'd be obliged if you

00:03:57 could provide us with some guidance comments on the above note issued in November 2008. And he's

00:04:02 referring to the tapered roofing insulation guidance that we just looked at. And he says this,

00:04:07 for some weeks now we've been aware of the guidance note and we've no issue at all with the message

00:04:12 that it delivers. What does concern us, however, and may concern other tapered insulation

00:04:16 manufacturers, is that the style and presentation of the note, as evidenced by the attached download

00:04:22 taken from the Kingspan website and its potential commercial implications, and he has a copy of the

00:04:28 guidance, there is evidence, albeit anecdotal, that in linking in this fashion with a manufacturer

00:04:35 could provide them with what could be considered an unfair advantage in this market. The fact that

00:04:40 the LABC and the name manufacturer are linked in the same document could confer upon the manufacturer

00:04:47 a preferential status to the detriment of others operating in this segment of the flat roofing

00:04:51 market. The fact that possibly they may have been very instrumental or helpful in developing the note

00:04:57 is very commendable, but we would question if it is appropriate for the LABC to then be seen as

00:05:03 providing some kind of pseudo endorsement to the manufacturer in this fashion. Surely the LABC have

00:05:09 to be completely neutral and seen to be neutral, and whilst we are sure that no endorsement is

00:05:14 meant, it could certainly be construed from this another activity by the manufacturer in the

00:05:18 marketplace. This kind of sponsorship is not something we've ever seen before,

00:05:25 and then he says the latest evidence of such activity we would offer of this is an article

00:05:30 in the Roofing, Cladding and Insulation magazine from March 2009 referring to the note and inviting

00:05:36 visits to the manufacturer website, not the LABC, to download a copy. Linking to a manufacturer in

00:05:43 this fashion also discourages other manufacturers from displaying the notice and spreading the word,

00:05:48 as we are unlikely to carry a note with the logo of a competitor manufacturer on our website.

00:05:54 We will appreciate your comments. Now, do you remember seeing this email in April 2009?

00:06:03 I don't recollect the detail of it, but I do think that there was subsequent

00:06:15 to its receipt, and in the process it was agreed that manufacturers should not be recognised in this way.

00:06:23 Right. Do you remember discussing it with Mr Everall, the Chief Executive?

00:06:30 No.

00:06:32 Did you at the time think there was any merit in the concerns being raised about the LABC's neutrality

00:06:38 in terms of these activities?

00:06:41 Yes, but I think there was a discussion around it was fair to acknowledge where someone had been

00:06:50 helpful, but we did accept that this was perhaps a little bit more than should have occurred.

00:06:59 So what was a little bit more than should have occurred?

00:07:01 Displaying the logo.

00:07:03 Yeah, yeah. Now we can see from the documents that Mr Hall sent a further email on the 5th of May 2009

00:07:12 asking Mr Everall to acknowledge receipt and provide a response to the email that he'd sent

00:07:16 in April for the transcript that's at LABC 308172. Mr Hall then sends a further email on the 10th of

00:07:25 June 2009 chasing for a response again for the transcript that's at LABC 308173.

00:07:34 And then we can see a further email that Mr Hall sends on the 24th of September 2009 if we go to that

00:07:41 LABC 308178.

00:07:48 And he says to Mr Everall, you're not copied into this, it's at the top of this page September.

00:07:53 Dear Mr Everall, I suspect that you have other issues that are more pressing than responding to

00:07:57 my inquiry and that I have taken that into account when considering the length of time taken from my

00:08:03 original inquiry to the fact that I appear as of today, 24th of September, not to have received a

00:08:08 reply. Do not mistake our lack of chasing activity as an indication of any diminution of our interest

00:08:14 in this matter. My original email was sent back in April. Can we expect any reply, a reply,

00:08:23 at all? If the answer is in the affirmative, when might we expect such a reply to be provided?

00:08:30 And then you are the person that finally responds on the 2nd of December 2009, so many months after

00:08:37 this complaint is raised. And that appears at LABC 308182. And I want to look at the bottom of page 1.

00:08:47 So this is from you to Mr Hall, CCing Mr Everall, December 09, and you say, dear sir, I refer to

00:08:55 your emails addressed to the Chief Executive Officer of LABC, expressing concern over the

00:08:59 inclusion of the Kingspan logo on our guidance note relating to tapered roof insulation.

00:09:05 I would advise that LABC is a private members organisation where membership is voluntary

00:09:10 and our principal role is to support members in their interpretative work, and I would advise

00:09:15 members in their interpretation and application of building control legislation. The guidance

00:09:20 note referred to was produced as a result of differing interpretations of the legislative

00:09:24 requirements for calculating the thermal properties of flat roof constructions. Discussions were held

00:09:30 with the technical department of Kingspan in order for LABC to gain an industry view on the problem,

00:09:36 and it was considered appropriate to recognise the help given by the company in this way.

00:09:41 As a private company, LABC reserved the right to engage with industry where it is considered

00:09:46 beneficial to the aims and objectives of the organisation. However, we do recognise your

00:09:51 concerns and had perhaps not appreciated the wider issues that you raise. Guidance notes produced by

00:09:58 LABC are intended for members' use. While there is no restriction on circulation, then we go over

00:10:04 the page, within the public domain, this is not the fundamental purpose of such notes and it is

00:10:09 for others to consider the guidance as they see fit. The guidance note has now been available

00:10:14 for some time and we do not wish to withdraw the information. Having previously agreed to include

00:10:20 the Kingspan logo, we do not consider it appropriate to remove it in this instance.

00:10:25 We will, however, take your concerns into account should we produce guidance with industry

00:10:30 assistance in the future. Do you see that? Yes. Now, is it fair to say that

00:10:38 you are saying in that email that you understand the concerns and to some extent you accept the

00:10:42 concerns, but you are also pushing back quite hard in that email about this point, aren't you?

00:10:48 You are defending the LABC's position. Yes.

00:10:55 Can you explain why did it take you so long to respond to him, him having raised these

00:11:00 complaints in April 2009? No, because the original correspondence wasn't to me.

00:11:10 Why not remove the guidance and reissue it without the Kingspan logo?

00:11:15 I don't know. I have no recollection of the discussions. Presumably there was some feeling of

00:11:25 of... and we... remaining on an agreement made to show the logo, I don't recall.

00:11:36 So you are speculating about why you didn't do that? Yes. I see. Looking at this now,

00:11:44 can you see why concerns were being raised about... Well, I acknowledge that in the letter.

00:11:48 Yeah. And the extent to which it looks like the LABC are giving Kingspan preferential treatment

00:11:55 by partnering in this way. Acknowledged in the letter. Yes. So you agree that?

00:12:00 I've acknowledged it in the letter. Right. And at the top of the page we can see Mr. Hall's

00:12:05 response to your email. He's responded promptly on the 2nd of December 2009.

00:12:13 Thank you for your reply. Much appreciated. There are trade organisations that represent

00:12:17 insulation manufacturers and roofing system suppliers. Might I suggest that should you

00:12:22 feel the necessity to consult in the future, and I agree that this is a very necessary step,

00:12:30 that you deal with a trade organisation and not one individual company who have, in my opinion,

00:12:36 used this situation to further their own particular agenda. We are not happy that this

00:12:41 continues to be circulated with the Kingspan logo, and I would ask that in the light of our concerns

00:12:46 that you reconsider the position. If our points do have merit, as you suggest, then I do not think

00:12:52 it unreasonable to seek not the withdrawal of the notice, but the withdrawal of the Kingspan logo.

00:12:58 I'm sure if approached the Thermal Insulation and Manufacturers Association, who endorsed the

00:13:03 document, to the benefit of all and not a minority interest. Look forward to your reply, Chris Hall.

00:13:10 And then your response to Mr. Hall appears at, if we go to a different document, LABC 308183.

00:13:22 It's in the second half of page one. It's the third of December.

00:13:30 And you say, dear sir, I refer to your message below, the contents of which are noted. I would

00:13:34 advise that as the technical content remains relevant, we will not be withdrawing the notice

00:13:39 or amending recognition of those involved in its production. And then at the top of the page,

00:13:46 Mr. Hall says, dear Mr. Turner, while I'm grateful for your prompt reply, we are still not satisfied

00:13:51 that this is an appropriate response. We may well consider other avenues to raise our concerns more

00:13:55 formally elsewhere. So he was not satisfied with your response, was he? Obviously not.

00:14:03 Do you accept that the LABC must be neutral and must be seen as being neutral?

00:14:08 Yes, but we also have a problem in identifying who and what in a competitive environment.

00:14:24 Yes, but why wasn't Mr. Hall's response to that the right one, which is if you need to

00:14:29 issue guidance like that, you consult with wider trade organisations who represent a number of

00:14:35 different companies rather than going to one company only? That was a very good point. We

00:14:42 had those contacts, as I've said before, through the various working groups which we were on.

00:14:51 They were the ones that were open to discussion at that time, and it's just an avenue that was

00:14:59 followed innocently. You mean Kingspan were the ones that were open to discussion at the time?

00:15:06 Kingspan were party to the discussions on thermal performance of buildings

00:15:13 at the various working groups, along with others. I honestly don't know whether Timsor

00:15:18 were represented there. I would rather guess that they were. They didn't, or it didn't,

00:15:30 materialise that those discussions were taken with those people. That's just the way that

00:15:39 it came about. It wasn't pursued in any particular, certainly not by LABC, in any particular way,

00:15:47 but by the same token, we had to make ourselves noted in the public eye.

00:15:55 I don't know whether...

00:15:59 Well, someone's gone, honestly, to speak to the workmen who are dealing with it. Do you want to

00:16:05 wait for a minute? It stopped temporarily, at least. Shall we see how we go?

00:16:11 Yes. Shall I carry on for now? After he came back to you, Mr Hall, and said he wasn't happy,

00:16:17 and why don't you go to the trade associations, something you've admitted was a good point,

00:16:22 did you actually give any consideration within the LABC to doing that very thing,

00:16:27 to approaching trade organisations about this guidance, to see if they would partner with you

00:16:32 instead? I think it was something that was done, it was something that was

00:16:42 passed, and it's something that would be taken into account for future. It wasn't seen as

00:16:52 a pressing point to change it at that time. That's my recollection.

00:16:58 Did you ever go back to Kingspan and say we've had concerns raised about having your logo on

00:17:02 our guidance? We'd like to discuss with you whether that's appropriate, and perhaps whether

00:17:07 we ought to go to a wider trade organisation. I couldn't say whether that happened or not.

00:17:13 We can see from an email exchange between you and Ms Cruz, if we look at this, LABC 308174.

00:17:22 You were due to have a meeting with Kingspan on the 18th of August 2009.

00:17:30 You can see that from the top email. You say to Ms Cruz in 2nd of July 2009,

00:17:35 can you add this to the agenda for the TWG? What was the TWG?

00:17:39 Technical Working Group.

00:17:41 I can't meet them on the dates given and have suggested 18th of August when I'm likely to have

00:17:45 a meeting with Kingspan at Lupus Street. Do you remember what you were meeting with Kingspan to

00:17:50 discuss in July, August 2009? I have absolutely no idea.

00:17:56 Okay. Can we look at another email now, LABC 308186.

00:18:07 These are emails in December 2009. The second email down on page 1 is you to somebody called

00:18:15 Jamie Rich, who we think was a marketing assistant at LABC. The email is headed Re Outlook.

00:18:23 You say, hi Jamie, I'm working on something with Kingspan, but it won't be for this month.

00:18:27 I will have an announcement, a new guidance note, but that will only be a couple of lines.

00:18:31 See what I can do tomorrow. Do you remember what was Outlook? Was it a publication?

00:18:40 It was a periodical, not magazine, but information sheet distributed to members, member authorities.

00:18:52 It was a member organisation publication.

00:18:58 Yeah. So were you working on an article with Kingspan for that publication?

00:19:03 Certainly looks like it.

00:19:04 Yes. And can you remember what the topic of that was?

00:19:06 No idea.

00:19:07 No.

00:19:08 At that time, there was huge focus on thermal performance. Members were desperate for

00:19:17 information on how to meet the new requirements of the regulations.

00:19:21 Yes. So you were collaborating with Kingspan on some guidance in relation to that area, were you?

00:19:27 It would appear so, yes.

00:19:28 Yeah. If we look at another email exchange, LABC 302330,

00:19:35 it appears that in March 2010, you're collaborating on another guidance note with Kingspan.

00:19:43 Second email down is an email from you to John Garbert. He's the head of marketing at Kingspan.

00:19:48 We've mentioned him before. CC-ing Philip Hammond. And you say, good morning, John.

00:19:54 Attached is the proposed guidance note with the amended last paragraph. I've made a minor change.

00:19:59 It's maybe a personal choice rather than anything else, but hopefully puts a positive rather than a

00:20:03 negative angle on the need to comply. I've also added a comment at the end to indicate that the

00:20:08 note is in relation to the provisions of Part L only, hopefully to avoid challenges against other

00:20:13 aspects of the regulations that may on rare occasions need to be taken into consideration.

00:20:18 Changes are in red. If we can agree on this, I think we're there and can format the finished

00:20:22 article and circulate to members. So as you've just explained, it would appear that you're

00:20:29 working on a guidance note with Kingspan relating to Part L of the building regulations. Is that

00:20:34 right? Yes. How did that fit with what you'd said to Mr. Hall in December 2009 that you were going

00:20:42 to take his concerns into account should you produce guidance with industry again in the future?

00:20:47 Yes. Mr. Hall wasn't a member of the various working groups. I think,

00:20:58 but I may be wrong, I think that was associated with information that was being produced by

00:21:04 the Zero Carbon Hub, which again was all thermal insulation and sustainability focused.

00:21:12 And it was an avenue of

00:21:18 availability at the time and

00:21:24 past information was not followed up on. I think the

00:21:34 the approaches were such that it was easier to work with those people that came to you rather

00:21:46 than go searching for others. That may be the case. So it was easier to work with Kingspan

00:21:52 because they were coming to you to talk about this than it was to say go off and find

00:21:57 representative trade organisations that you could collaborate with? That's a possibility, yes.

00:22:02 And did that occur to you? You're now some time on from the complaint that Mr. Hall raised in

00:22:10 April 2009. You've acknowledged his complaint in December 2009. We're now in 2010. Why not at least

00:22:17 try and find those trade organisations and ask to collaborate with them rather than one company?

00:22:24 Trade organisations were very similar to LABC in that they are representative of

00:22:34 members and they don't necessarily have a technical group or technical

00:22:43 committee or technical person of that association that we could link with in an easy fashion.

00:22:53 Manufacturers tend to have technical departments and it was the technical information that we were

00:22:59 seeking. Right, I see. But are you saying that trade organisations wouldn't have the necessary

00:23:13 expertise to be able to collaborate with you? They would within their organisation but we would end up

00:23:21 working with one of their members who would be an employee of another organisation. So we would end

00:23:30 up dealing in a similar fashion with an alternative manufacturer. Now I'm not saying that's wrong

00:23:38 but we wouldn't necessarily and that person would represent the trade organisation but we'd still be

00:23:45 working with an individual company. Yes but at least then when you issue the guidance it's being

00:23:49 issued on behalf of you and the trade organisation rather than you and a company, a specific company.

00:23:55 Yes you can say that now and it's easy to understand that now but at the time shall we say it was the

00:24:03 route of least resistance. But you'd had complaints raised about it didn't you? So

00:24:09 you weren't unaware that this was causing consternation within the marketplace were you?

00:24:15 I obviously didn't take them into consideration during these discussions.

00:24:22 There's a further exchange between LABC and John Garber on the 28th of April 2010. If we go to that

00:24:28 LABC 302333.

00:24:37 Again this is the second email down. This is Philip Hammond to John Garbert. The subject here is

00:24:43 general advice on building REGs. Hi John, just so you know Barry has approved the document for release.

00:24:48 We'll add to our website then tell all our members and surveyors about it. After that

00:24:53 we'll face it to external audiences and then John Garbert says to Mr Hammond at the top,

00:24:59 thanks Phil I'll do my utmost to remember to let you see whatever we put on this.

00:25:07 Can you help us? Was that exchange referring to the same piece of guidance or a different piece

00:25:11 of guidance with Kingspan at this time? I couldn't tell you. One would assume so but I don't know.

00:25:19 We can also see from the documents that you had a meeting with Kingspan with Richard Bromwich and

00:25:25 Chris George in December 2010 to discuss the National Federation of Roofing Contractors

00:25:31 competent person scheme for the transcript that's at LABC 2019652.

00:25:38 Can we look at another email at LABC 0019658?

00:25:54 We can see this is an email you send. This is now into 2011 now, March 2011. You to Mr Everill,

00:26:01 your chief exec at the top and then you say thank you Paul. Yesterday fitted in well and the lunch

00:26:07 break was perhaps more productive for LABC than the seminar itself. Excellent discussions with

00:26:13 Kingspan, MPBA, BBA and members of DCLG, even RDLABE and BCA. Enjoyed my day, hope you did too.

00:26:22 And this appears to be some kind of seminar you've attended on energy performance of buildings,

00:26:27 evidence and feedback. Do you remember attending that seminar and having excellent discussions

00:26:33 with Kingspan? It wasn't just Kingspan was it? There were numerous

00:26:45 seminars, meetings about energy performance during that time

00:26:53 and there was discussions with many people there, not just Kingspan. So that was just a report on

00:27:02 the way that the day went and the people that I spoke to. Yes but that doesn't provoke a memory

00:27:08 about what your excellent discussions with Kingspan were at that particular conference. Well there

00:27:12 were excellent discussions with BBA and DCLG as well. Yes, fair enough. So it was about

00:27:18 understanding the regulations not about any particular guidance note. Yeah now just going

00:27:24 back to what you said in your statement that I showed you right at the beginning, you said

00:27:28 I have limited engagement with product manufacturers. Now looking at what we've just looked at,

00:27:34 the collaboration that you had with Kingspan, the meetings you had with them,

00:27:38 do you accept that that significantly understates the extent of your relationship with Kingspan

00:27:43 during this period? My relationship with Kingspan was purely technical and they were

00:27:50 providing expertise in an area that was becoming a lot more important to building control by way

00:28:00 of thermal performance and they just happened to be there and available at the time. So whilst that

00:28:07 may be an understatement, it was not my position to go chasing

00:28:13 manufacturers, it just so happens they were the ones that were easily accessible through all the

00:28:20 various groups that I was partaking in at the time. Yes. And just seemed to be there at the time.

00:28:30 And would it be fair to say that you were frequently engaged with Kingspan between 2008 and 2008?

00:28:37 And would it be fair to say that you were frequently engaged with Kingspan between 2008 and 2011?

00:28:47 Yes. Did your relationship with Kingspan and that positive dialogue you were having,

00:28:54 say, over thermal requirements, do you think with hindsight that might have affected

00:28:59 the way you responded to concerns which were raised about Kingspan's

00:29:05 statements over their fire performance? Oh yes, with hindsight. In what way? Can you help us?

00:29:14 The ways that's already been discussed. I can't elaborate on what's previously been discussed

00:29:21 but with hindsight there may well have been undertones and there may well be a reason why

00:29:28 they were always in attendance, in view, readily available at various working groups. I don't know.

00:29:43 But that seems to be the case that they were the ones that were more readily available than

00:29:50 other manufacturers for the thermal performance information that we were looking for.

00:29:56 Yeah. I think what I was putting to you was that do you accept that that affected the way you then

00:30:01 responded to concerns when they were raised about Kingspan's fire performance statements?

00:30:08 Yes. Yeah.

00:30:12 There was something called an LABC business sponsorship package at this time. Do you recall that?

00:30:20 I'm aware of it. And a proposal for such a sponsorship package was put to Kingspan.

00:30:26 If we can go to LABC 302324. Now we can see from the top this is an LABC business sponsorship package

00:30:41 proposal to John Garbet, marketing director Kingspan installation. Now the document's not dated but

00:30:48 from some information on page three of it, which we'll come to in a moment, it appears that the

00:30:53 sponsorship agreement would run from the 1st of November 2009 through to October 2010. So that's,

00:31:00 it's got to have been some time before that that this sponsorship package was pitched.

00:31:06 And if we look at overview and these first few paragraphs it says LABC is a non-profit making

00:31:12 company limited by guarantee. Its principal source of income is subscriptions from local

00:31:17 authorities to pay for the technical policy, legal services, marketing and lobbying functions

00:31:22 undertaken by LABC on behalf of local authority building control departments in England and Wales.

00:31:28 We have a business development and marketing team. The services are delivered by local authority teams

00:31:33 and therefore the revenue from sales goes directly to our members authorities. Consequently LABC has

00:31:39 no sales income to reinvest in marketing communications to help keep subscriptions

00:31:45 down and effectively to stop the burden of marketing being passed back to council taxpayers.

00:31:51 LABC seeks commercial partnerships and business sponsorship to help pay for marketing to industry.

00:31:58 Business sponsorship packages provide a simple and direct channel for manufacturers and service

00:32:02 providers to communicate with LABC's surveyors and their customers. Payment of a sponsorship fee

00:32:08 simply pays for LABC's communication costs and helps us to run sales activities, events,

00:32:13 publications and our various online activities. And below that there's a section headed no bias

00:32:22 or exclusivity. If you just look at that section it says LABC's market position is largely based

00:32:30 on its independence and technical impartiality. So whilst we are very happy to help promote technical

00:32:35 knowledge and awareness of systems and solutions we do so to encourage quality design and construction.

00:32:41 We cannot offer business sponsors exclusive access and we will work with any reputable company etc.

00:32:48 But then it goes on however LABC believes that building control has to engage with manufacturers,

00:32:52 service suppliers, designers, specifiers and contractors. The climate change agenda is creating

00:32:57 a huge amount of innovation and the variations we see in projects and on site is almost infinite.

00:33:03 Therefore we need and value input from industry. LABC welcomes support from all parties to help

00:33:09 advance our knowledge enabling us in turn to provide better advice to our customers.

00:33:14 And then it outlines in section c the benefits of sponsoring LABC.

00:33:20 4000 you get direct outreach to 4000 LABC surveyors and technical support staff,

00:33:27 3000 special customers registered as partner customer accounts etc. It goes on.

00:33:33 And then if we go over the page to the next page

00:33:48 we can see that a business sponsorship package is then outlined for Kingspan. I'm not going to go

00:33:54 through all the detail of it. There's two parts we can see it's events, conferences and LABC

00:34:00 building excellence awards and then it's LABC member and surveyor communications.

00:34:09 And then if we go on to page three

00:34:17 we can see what's involved in that and I just want to look at the penultimate bullet point on that

00:34:24 page beginning direct support if we could zoom in on the second half of the page.

00:34:29 It says that one of the benefits is direct support to our technical working group via Barry Turner

00:34:34 and its chair Mike Sansom for technical policy clarification to the LABC network.

00:34:41 The technical working group is LABC's clearinghouse to identify difficult or unusual technical issues

00:34:46 where LABC network is being inconsistent or needs a policy. Topics tend to be very detailed and

00:34:51 specific and the working group will take external help and advice to define a policy position. So

00:34:57 you're specifically named in this sponsorship package and then we can see that an offer is made

00:35:05 it says it under terms and period the sponsorship package defined above is offered at 12,500.

00:35:11 This money will be ring fenced etc in the bottom and if we go below that we can see it says the

00:35:20 next awards cycle starts immediately after this year's national building excellence awards in

00:35:25 October. The counties and regions immediately begin their next cycle of local awards culminating

00:35:30 in the next year's national awards in October therefore the sponsorship agreement will run

00:35:34 from the 1st of November 2009 through to the 31st of October 2010. Now were you aware of this

00:35:42 proposed sponsorship package to Kingsbound at the time? I was probably aware of it.

00:35:49 I had no input into it.

00:35:51 Why was a bespoke business sponsorship package targeted at Kingsbound in particular? Can you help us?

00:36:01 I had no budgetary responsibility, no responsibility to generate income and did not promote or

00:36:15 not promote did not make any sales pitches that is not my document I cannot answer for it.

00:36:23 Were you ever involved in any discussions about whether such business sponsorship packages

00:36:28 risked prejudicing LABC's independence from manufacturers? It was a difficult line for us to

00:36:39 for us to to follow on a difficult path because because we had a need for income

00:36:49 to be able to promote local authority building control in a competitive market

00:36:57 there needed to be income from somewhere it wasn't provided by government and it certainly

00:37:04 wasn't provided by local authorities and so this was a you know one of many

00:37:13 methods by which some form of income could be generated in order to promote those services

00:37:22 it wasn't part of my remit and I can't answer for that document. Were you ever aware of any

00:37:29 steps being taken to safeguard against an erosion of LABC's independence given sponsorship deals

00:37:38 like this one? It was always a thought process and it's not an answer that I'm aware of at any rate

00:37:55 that we ever really got to grips with there were other companies that we used for information in

00:38:07 much the same way it was a sales and marketing promotion business agreement that I wasn't party to.

00:38:20 Does it follow from that answer that you weren't aware of any steps being taken specific steps to

00:38:26 protect LABC's impartiality and independence despite these sponsorship deals? I think the

00:38:33 questions were asked but I can't tell you what the what the resolution was.

00:38:39 Yeah and can you help us as to whether this particular package was accepted and agreed

00:38:45 by Kingspan? I can't I don't remember it coming to fruition but I again it was not part of my remit.

00:38:59 Right we've seen a spreadsheet for the transcript that's the LABC 308181 that suggests that the

00:39:06 total income generated from commercial partnership with Kingspan was as quoted here 12,500 but you

00:39:14 can't help us. You've got more information than I have. Right okay thank you. Just looking before

00:39:20 we leave this proposal if we go back to the bottom of page one we see the section again

00:39:28 benefits of sponsoring LABC and if we go over the page and just look at the second paragraph down

00:39:35 it says that Kingspan installation will benefit from increased brand awareness and brand reinforcement

00:39:41 and provide the opportunity to gain personal experience through presentations and meetings

00:39:45 with Kingspan's insulation team as well as fostering increased product knowledge and

00:39:49 technical understanding our contact with the marketplace will provide an indirect route to

00:39:53 sales through referrals. Do you see that? Yes. And again was that your understanding about what one

00:40:00 of the benefits would be to Kingspan of sponsoring in this way? No not my understanding at all it's a

00:40:06 sales pitch which I was not party to so I can't answer for the wording

00:40:17 it was necessary to generate income if that was the way that it was

00:40:22 had to be done then presumably that is the case but I can't answer for that document.

00:40:28 If we just look at an email chain LABC 302326

00:40:36 and we look at the bottom of the page there's an email 17th of November 2009 from Philip Hammond

00:40:43 to John Garbutt now and the subject is are you supporting LABC now to be clear you're not copied

00:40:48 in on this email but it says hi John we seem to be giving you good coverage I was just reading

00:40:53 the proof of Phil Heath's flood piece my next awards cycle is kicking off now and I'd like to

00:40:59 be able to announce to LABC members and surveyors that Kingspan insulation is sponsoring LABC

00:41:05 is sponsoring LABC we're also finalizing the speakers and sessions for our main

00:41:10 member conference early in February have you been able to make a decision

00:41:16 do you know what good coverage he's referring to there he says we seem to be giving you good coverage

00:41:22 no no John Garbutt's response is is one email up

00:41:28 he says this he says to Philip Hammond Philip Philip we are I have just been dotting the eyes

00:41:34 and crossing the t's I will have an order number for you shortly would it be wise for us to meet

00:41:39 up to hammer out who needs to do what when going forward would you and Barry like to come out and

00:41:44 see us and meet all involved from our side and see what we do perhaps we can also discuss the

00:41:49 guidance note that is with Barry we are keen to get that out on the streets

00:41:54 do you remember ever going to to meet them to see what they do around this time

00:42:03 I have no recollection of

00:42:08 meeting them that doesn't mean to say it didn't happen but I don't recall it we can see one email

00:42:16 I don't recall it we can see one email up

00:42:21 Phil Hammond then says John great news I'll speak with Barry and see if we can get a choice of dates

00:42:26 and then right at the top this is actually we think from a private email associated with Phil

00:42:34 Hammond that explains the email address he says it appears that Kingspan will become our new

00:42:41 national sponsor of awards for 2010 you're sent that email we need to get a meeting and

00:42:47 announcement ASAP do you remember Kingspan becoming the national sponsor of the awards for 2010

00:42:54 no again did that sponsorship involvement of Kingspan impact on the LABC's decision

00:43:03 to investigate the concerns which have been raised by third parties about the k-15 certificates

00:43:09 no because I didn't tie the two together I was not involved in this discussion or this sponsorship

00:43:16 discussion yeah and I want to move on to ask you about the registered details certificates which

00:43:23 were issued for k-15 so we know that you changed from what you call the type approval system to

00:43:29 the registered details system I think you tell us in your statement it was around 2010 that change

00:43:34 was taking place is that right again the my statement is based on documents and information

00:43:43 provided to me not necessarily personal involvement

00:43:50 I see so what was the extent of your involvement in the registered details schemes as the

00:43:56 the lead technical I thought I've already described that it's exactly the same as it was for the

00:44:05 certificates right and can you explain briefly what prompted this change to this scheme called

00:44:11 the registered details scheme why was there this change because then because of the name again as

00:44:16 I've explained earlier about the use of the word certificate was was not correct because we're not

00:44:23 a certification body I see well um let's look at the registered details manual now

00:44:33 um this is a h hbc six zeros 23

00:44:45 if you go to the next page you should see the front page there is the labc registered details manual

00:44:54 and

00:44:55 it's right isn't it that that this manual was designed for the benefit of the local authority

00:44:59 undertaking the research for the registered details certificates is that right that's my

00:45:05 understanding and we can see if we go to page four

00:45:13 top of the page that's made clear here in this introduction it says thank you for agreeing to

00:45:18 act as research authority in respect of a registered detail certificate and that's

00:45:24 the application and then underneath that this brief manual sets out the process and procedures

00:45:29 of a typical registered detail application clearly depending on the complexity of certain

00:45:35 applications and reply times from applicants so that's the purpose of this document and were you

00:45:42 familiar with the contents of it not particularly no why not because it was developed by others

00:45:50 but did you ever read it in your time at the labc

00:45:56 it's not a process or document that i had day-to-day involvement in so did i read it

00:46:05 yes did i digest it no okay and if we look at the fourth paragraph down here in this introduction

00:46:13 in this introduction we can see it says this once a registered detail certificate

00:46:19 and note it is still called a certificate yes in this manual probably a cut and paste error but

00:46:28 that's an assumption well it says once well if it's a cut and paste area i think it appears a

00:46:33 number of times in this document we can see it appears for example in the beginning of the

00:46:38 paragraph above registered detail certificates last for 12 months but anyway continuing with

00:46:44 that fourth paragraph it says once a registered detail certificate is awarded the type system or

00:46:49 solution will be recognized by all local authority building control departments across England and

00:46:54 Wales therefore it is important that the application i should say is thoroughly considered and the

00:47:01 procedures detailed below are closely followed so again is that your understanding that once you've

00:47:06 got that registered detail certificate that type system or solution will be recognized by all

00:47:14 labc building control department departments across England and Wales yes that that wording

00:47:19 is very similar to the previous document that you've that you've referred to and this is

00:47:28 an updated version of that so i would assume that a lot of the wording will be very similar

00:47:34 yes it is but i think you said earlier that some of that wording you weren't very comfortable with

00:47:39 because it didn't necessarily reflect what you thought ought to happen

00:47:42 did you ever raise concerns about this wording i don't recollect that i was consulted on the

00:47:48 wording of the document and then if we look just for now there's a section called independent

00:47:56 certification schemes it appears at page 19 of this manual and we'll come back to this manual

00:48:02 a few times you see their independent certification schemes in the middle of the page

00:48:08 and in the first paragraph it says there are many uk product certification schemes for example bba

00:48:13 and bre schemes these schemes certify compliance with a registered recognized document british

00:48:19 standard etc it does not mean that if a product is not certified with one of these schemes the

00:48:24 product is not suitable it is a common misconception that all products need say a bba certificate this

00:48:31 is not the case but a bba certificate does provide absolute assurance and materials should

00:48:37 not then be interrogated further do you see that yes were you involved in agreeing that that was

00:48:45 an appropriate approach once you've got a bba certificate don't interrogate further no i did not

00:48:52 use that wording or was not consulted on that wording but it was a general belief

00:48:59 throughout the building control industry both public and private that bba certificates were

00:49:11 a good indication and could be relied upon did anybody ever raise a concern that the problem

00:49:19 with that might be that if there was an error in the bba certificate that error would just simply

00:49:23 get perpetuated if there was no interrogation whatsoever it was not for building control

00:49:30 to interrogate bba that is policed by a different organization they they they are a a certification

00:49:39 body notified by ucas it's for ucas to police bba not building control but what if there was a

00:49:46 patent error on the face of the bba certificate would you have expected building no i would not

00:49:51 expect building control to do it we're not scientists we're not test laboratory technicians

00:49:58 we rely on their certification for their information it is not for building control

00:50:04 to police those certificates let's just look at an email now that you sent to mr ewing in

00:50:11 october 2012 if we go to labc three zeros four eight nine three

00:50:24 now this email is part of a wider email chain in relation to an email received from the office

00:50:28 of fair trading the oft and i just want to show you what you said to mr ewing in the

00:50:34 fourth paragraph of this email this is you to mr ewing copying in miss stimpson in october 2012

00:50:42 and it's about an oft statement which you're referring to in the first paragraph and you

00:50:50 suggest a form of words and you say in the second part of that i must stress that labc do not test

00:50:57 or certify insulation products our registered detail process is an impartial expression

00:51:04 of compliance with building regulations based on testing and information provided by uk or eu

00:51:09 accredited testing stations all construction products are constrained by regulatory requirements

00:51:15 which may restrict how compliance can be demonstrated this restriction can itself

00:51:19 become a barrier for innovative products so while we support competition for the certification of

00:51:24 insulation products innovations and subsequent certification must demonstrate compliance with

00:51:30 the constraints of the regulatory framework do you see that there yes now does that accurately

00:51:36 summarize in your view the intended purpose of the registered detail system

00:51:49 yes yes in that first line of that paragraph i just read you say i must stress that labc do not

00:51:57 certify insulation products if that's right what are the type approval and registered detail

00:52:05 certificates for kings band k-15 and celotex rs 5000 if they're not certificates for insulation

00:52:12 products yes i think it is poorly worded but the meaning for that is um we do not provide

00:52:23 as i've said we're not a certification body approved for that purpose within the uk so we

00:52:31 do not provide a laboratory type certificate to say that a product when tested to a certain

00:52:46 standard meets certain requirements we rely on the testing laboratory to provide that certificate

00:52:57 that's what's meant there and which is why as i've said the word certificate in terms of the

00:53:06 registered details etc and type approvals was an incorrect use of the word

00:53:17 um but there i'm not saying that we you know uh the meaning there is that we're not providing

00:53:31 a ukass accredited certificate to say that a product has met certain standards

00:53:39 right i see but you accept that that bold statement that you've made there at the beginning of that

00:53:44 paragraph is it's much more nuanced than that what you're saying isn't it because you do issue

00:53:50 certificates the way that i've worded that you know yes it could be better but the um um the

00:53:58 you misconstrue the meaning that was intended okay let's look now at the registered detail

00:54:05 certificate which was valid for the k-15 product from the 28th of august 2013 until the 28th of

00:54:13 august 2014 now i'm just going to summarize the events that led up to to that certificate

00:54:20 i want to summarize some of the chronology just for efficiency sake so what we know is that on the

00:54:26 14th of april 2011 kingspan inquire about updating their old system approval to become a registered

00:54:34 detail for the transcripts that that's at labc 301970 page three then on the 7th of june 2011

00:54:46 mr mills of kingspan inquires about the timeline for a new approval for the transcript that's at

00:54:52 labc 301970 and then on the 7th of june the same day 2011 labc email kingspan confirming what the

00:55:03 registered details process is that's at labc 301939 and then i want to pick it up on the 9th of june

00:55:17 if we can go to labc 302397

00:55:23 and i want to look at the bottom of page one and on to page two

00:55:30 so martin taylor at the labc can you help us as to what mr taylor's role was

00:55:38 it was

00:55:44 i think at that time sales promotion right and he says uh hi david and then we go over the page

00:55:52 so this is to david jones at herefordshire we've received two requests recently regarding the

00:55:57 registered details from kingspan the first for cool therm k-15 via gareth mills and then the

00:56:03 second for something called the kingspan tech building system via justin davis and there appears

00:56:09 to be a little confusion regarding the move to registered details and the possibility to combine

00:56:13 a registered details check with an labc new home warranty check i think it will be therefore be a

00:56:20 good idea for me to meet with kingspan to discuss the whole product range to allow me to offer a

00:56:25 more attractive quote i can also advise them regarding other initiatives our labc are working

00:56:32 on around the green deal etc and then he says i appreciate you have a good relationship with

00:56:38 kingspan so it'd be good if you could also come along accordingly i would be grateful if you

00:56:43 confirm your availability so that's sent to mr jones and then if we go up the page

00:56:51 at the top of the page on the 9th of june martin taylor sends an email to mr davis of kingspan

00:56:56 confirming there's going to be a meeting on the 6th of july 2011 and he confirms that mr jones

00:57:02 of herefordshire will be in attendance and then we see an email if we go to labc three zeros two four zero two

00:57:14 we see an email from mr taylor to david jones you're not copied into this email or party to this email

00:57:24 but he says hi david further to our recent meeting at kingspan i've now been asked to quote on the

00:57:29 enclosed 21 systems i normally as discussed in the meeting quote 2005 under for each new system and

00:57:37 350 pounds for each renewal which in this case would be 48,200 so clearly unrealistic

00:57:44 as the research authority you receive one third of the agreed fee and i can by negotiation

00:57:49 increase this to cover additional checking etc

00:57:54 most of these already have bba certification which should greatly reduce you checking time

00:57:59 what i really need from you is an indication of whether you feel it'd be appropriate to do this

00:58:03 time what i really need from you is an indication of whether you feel it'd be appropriate as your

00:58:07 checking fee and a timetable for when you could complete the checking and then he says if you

00:58:12 don't have capacity i'll source this from elsewhere and he says in the final substantive paragraph

00:58:17 i'm looking to be as competitive as possible as this could establish strong links now in advance

00:58:22 of the green deal and if kingspan sign up for registered details others are likely to follow

00:58:27 so

00:58:30 now just pausing there do we take it from the fact that mr jones had been approached to assist with

00:58:37 this registered details work for kingspan that there had been no concerns raised within lebc

00:58:45 itself about mr jones's technical competence to carry out these kind of assessments

00:58:51 i don't think it's appropriate for me to answer that question because i was not party to this

00:58:59 process and the choice is made well i want to know whether you recall there being any concerns

00:59:06 about asking mr jones to do these technical assessments i have no recollection of that

00:59:13 now on the 17th of august 2011 if we go to labc three zeros two zero two one

00:59:21 mr jones responded to mr taylor's email about the fee query

00:59:31 and he says this he says sorry to delay things difficult to give a definitive response at this

00:59:34 stage mainly because we don't know exactly what it is we'll be getting a third of

00:59:38 however my initial reaction is this could probably be okay provided as we discuss at the meeting the

00:59:42 checking procedure does not require us to go outside the scope of the bba certificates

00:59:46 to any great extent other than to verify the assertions made in terms of building regs

00:59:51 compliance against other guidance now in fairness mr jones seems to think that he should at least

00:59:58 check whether the assertions made in in the bba certificates in terms of building regs compliance

01:00:05 in the bba certificates in terms of building regs compliance

01:00:08 were correct is that your understanding as well i can only read what is written there

01:00:18 i can't comment any more than that on what he says there sounds reasonable

01:00:24 yes and then if we pick it up at the end of that paragraph he just two lines up he says time for

01:00:29 some negotiation i guess as i agree it would be good to establish and maintain a strong link with

01:00:35 them given the market they are in now the emails i've just read to you show that there was clearly

01:00:45 a benefit to la bc from partnering or doing this work on registered details certificates for kingspan

01:00:52 because if kingspan sign up for the registered details scheme others are likely to follow

01:00:59 is that fair yes that's that's the assumption made in that in that correspondence and were you aware

01:01:05 that the la bc clearly wanted to establish what's described here as a strong link with kingspan given

01:01:11 the market they were in no that's not a comment that um i was aware of or i can comment on

01:01:22 now let's look at another email chain now at la bc 308243

01:01:33 this is an email of the 18th of august 2011 so this is still before the registered details

01:01:39 certificates issued it's martin taylor to anna sloper and he says hi anna i've attached the

01:01:48 kingspan quote can you add the register the rd registered details reference numbers in for me

01:01:53 and put the below into a letter to accompany the quote and then he says dear justin la bc registered

01:02:00 details i refer to our meeting on the 4th of july 2011 in respect of the above and to your

01:02:04 subsequent email of the 20th of july 2011 i enclose a fee quotation in respect of the registered

01:02:10 details process for your consideration for ease of reference and to hopefully make the process

01:02:16 affordable i've grouped the installation products together into roof wall and floor solutions

01:02:21 the quotation is set out to allow you to either select individual systems or a combination

01:02:26 whereupon the discount of 25 illustrated will be applicable to five or more systems instructed

01:02:32 together i've also as requested included a quote for all the systems as a whole for your further

01:02:38 consideration and then he goes on to explain that david jones of herifordshire has confirmed he will

01:02:45 be able to check all of the submission within a two to three week period dedicating himself to the

01:02:50 project full time and then he said goes down on completion of the registered detail checking

01:02:56 process it's hoped that the individual systems can be illustrated in the form of a compliance

01:02:59 guide or technical guidance notes which will both educate all la bc surveyors and allow kingspan to

01:03:05 promote your systems accompanied by our nationally recognized logo maybe we could consider a joint

01:03:11 promotion of the same and then he if we go down he then says i sincerely hope you find the quotation

01:03:21 acceptable so that's what he's proposing is sent and then underneath that we see some red text from

01:03:27 mr taylor and i want to ask you about this he says ana please let me know what you think to both the

01:03:32 letter and the quote launer thinks it's worth a try but i would appreciate your comments if we get

01:03:37 this one right it will be good for the bonus do you see that yes

01:03:45 and we can see from the attachment to that email

01:03:51 the invoice that's quoted for the registered details certificate

01:03:56 and that invoice totaled around ten thousand one hundred and fifty six pounds and 25 pence

01:04:02 um now from what mr taylor has said in the email there appears to be a clear financial benefit to

01:04:09 the employees of la bc if kingspan signs up to the registered detail scheme do you agree

01:04:17 again you're taking an inference from that comment i would suggest that that was a flippant comment

01:04:27 which is now being misconstrued and i do not agree and to my knowledge employees did not

01:04:37 get any bonus whatsoever based on these details right so you think that's just an off it's an

01:04:44 office banter comment that you are in taking the wrong inference from having seen this email do

01:04:52 you maintain that the la bc was impartial when it came to carrying out its assessments

01:04:57 of kingspan's product

01:05:02 there's obviously a working relationship

01:05:09 whether that um impacted on impartiality i i couldn't comment

01:05:23 so you just can't help us as to whether the significance of this work to la bc potentially

01:05:29 affected the extent to which the la bc were impartial in its assessments of these registered

01:05:35 detailed certificates i can't comment on that because i was not involved in this so this is

01:05:42 the first time i've seen this correspondence and the impartiality i would like to believe

01:05:53 was not affected but there was obviously a good working relationship and there was obviously a

01:05:59 need to get information and i can't i can't expand on that any further okay can we look at

01:06:09 an email now that you sent a couple of months or few months later in october 2011 if we go to la bc

01:06:16 0019679

01:06:29 this is an email of the 20th of october 2011 that you send to

01:06:34 steve evans of the nhbc we're going to come back to some exchanges with mr evans in due

01:06:40 in due course we've got mr bass in there etc and the subject matter if we could blow up the top email

01:06:55 can we zoom in to the top email sorry

01:07:04 there we go

01:07:10 and it says the subject is bca technical liaison action point 17th of october 2011

01:07:18 that bca is that the building control alliance yes it's being referred to there now i've i've

01:07:23 got a number of questions for you about the bca and about their technical guidance notes

01:07:28 we'll come to those in due course but looking at this email you say hi everyone

01:07:32 just to prove i haven't disappeared off the face of the earth i attached the query received from

01:07:36 rockwall last year sometime and our response regarding junction of a party wall with a roof

01:07:43 i think the description in the action list and what i was supposed to be providing may vary

01:07:47 slightly but this was the question asked and the response given it later transpired that rival

01:07:53 manufacturers were at war and it would have suited rockwall very nicely for us to agree with them

01:07:59 i later had cause to take issue with king span via a trading standards query over using our

01:08:05 opinion in advertising because it suited king span they chose to use our opinion in their

01:08:10 advertising something that was very quickly discouraged now can you just help us with some

01:08:16 of the background to this email because we're not clear on it at the moment when what are you

01:08:21 actually referring to there in terms of rival manufacturers being at war and taking issue with

01:08:28 king span via a trading standards query the challenge or the the query about for bca was about

01:08:37 the carrying of a

01:08:43 a

01:08:48 plastic based insulation material over the party wall

01:08:57 in a flat roof on flats which is very difficult to remember and explain i'm sorry it's there is a

01:09:06 a die in fact i think there is a now an improved diagram in adb as to the the principles involved

01:09:15 but you either take the party wall beyond the surface of the roof to provide fire separation

01:09:28 between flats either side of the party wall or there was a requirement for a non-combustible

01:09:38 material to be

01:09:43 300 millimeters either side of the party wall within the flat roof space

01:09:53 or

01:09:53 i think it was any material could be carried across dependent on the overall height of the building

01:10:04 okay but how had you um how had king span chosen to use lab's labc's opinion in their advertising why

01:10:15 in their advertising why was that a problem the the two things are not

01:10:22 um i rather suspect that is related to um i i don't think it's the same opinion

01:10:34 but it might be because the

01:10:38 uh the outcome was that you could use a their their manufactured material

01:10:48 across a cavity wall in within a flat roof i think for up to three story flats

01:10:56 and because we had made that decision on interpretation of a requirement of adb

01:11:04 requirement of adb they were they were using that um and and i was not happy with it

01:11:15 right i see and why was it quickly discouraged i again it's um

01:11:23 um

01:11:27 off off the cuff remarks um in terms of i would have uh sent an email to them and asked them to

01:11:38 stop stop doing it right i see okay um mr term that might be a good moment for the

01:11:46 afternoon break would it all right it would yes well it's a little early than usual but i don't

01:11:52 suppose you mind that uh mr turner will we'll have the break now we'll come back please at half past

01:11:57 three and while we're out of the point you're out of the room again please don't discuss for

01:12:02 evidence or anything relating to it to anyone and if you'd like to give the asha that'll be fine

01:12:09 thank you very much

01:12:22 thank you very much of australia please

01:12:39 you

01:13:09 you

01:13:39 you

01:14:09 you

01:14:39 you

01:15:09 you

01:15:39 you

01:16:09 you

01:16:39 you

01:17:09 you

01:17:39 you

01:18:09 you

01:18:39 you

01:19:09 you

01:19:39 you

01:20:09 you

01:20:39 you

01:21:09 you

01:21:39 you

01:22:09 you

01:22:39 you

01:23:09 you

01:23:39 you

01:24:09 you

01:24:39 you

01:25:09 you

01:25:39 you

01:26:09 you

01:26:39 you

01:27:09 you

01:27:39 you

01:28:09 you

01:28:39 you

01:29:09 you

01:29:39 you

01:30:09 you

01:30:39 you

01:30:40 you

01:30:40 you

01:30:42 you

01:30:43 you

01:31:07 would you ask Mr Turner to come back in please

01:31:12 All right, Mr. Turner, carry on. Thank you very much. Yes, for speaking.

01:31:36 Yes, thank you. Yes. Now continuing with the chronology leading up to this first K15 registered

01:31:41 certificate being issued in August 2013. Just for your background, what we see in the documents

01:31:47 is there's a confirmation email from Herefordshire Council agreeing to act as the assessing authority.

01:31:52 Then there's some delay in Kingspan providing the necessary information about K15 for the

01:31:59 assessment. And I want to pick it up on the 19th of June 2013. If we go to LABC 40893,

01:32:08 here we see an email from Mr. Jones to Mr. Brennan, Cathal Brennan, copying in Mr. Davis,

01:32:23 and he is attaching a copy of the completed registered details certificate for K15. And

01:32:34 we can see in the string below that that somebody called Colin Davis appears to have completed the

01:32:42 assessment on behalf of Herefordshire Council. That's in the middle of this page. We can see

01:32:48 Colin Davis is emailing David Jones, I've made the necessary alterations, I believe this is now

01:32:52 sufficient, etc. And then we can see from Mr. Jones' email again back at the top of the page

01:32:59 that he attaches three documents to the email. He attaches the Cooltharm K15 type approval summary,

01:33:05 revised June 13 document. He attaches an application pack, registered details application form for the

01:33:13 product, and then a commission pack compliance declaration form. Now the revised Cooltharm

01:33:18 K15 type approval summary appears at LABC 40894. And if we go to page three of this document,

01:33:34 just looking just above that B3 heading, we can see it says from the results it can be considered

01:33:43 as a material of limited combustibility and meets the criteria of a Class 0 classification

01:33:48 for surface spread of flame. And further down the same page, under the heading requirement B4,

01:33:55 external fire spread, it says since K15 can be considered a material of limited combustibility,

01:34:01 it is suitable for use in all situations shown on diagram 40 of ADB, including those parts of a

01:34:07 building more than 18 metres above ground. So the technical information in this summary remained

01:34:14 technically incorrect. Do you agree? Yes. And now moving forward in time, on the 20th of June 2013,

01:34:23 if we go to LABC 305132, Mr Brennan sends the compliance declaration form and technical details

01:34:34 for K15 for peer review. We can see this here from this email on the 20th of June. And we can see that

01:34:43 this email is sent to you three lines down in the CC list, you appear, Barry Turner, as well as a

01:34:51 number of other addresses of local authority building control personnel in different local

01:35:00 authorities plus LABC people themselves. And my question for you is, did you form part of the peer

01:35:09 review group? No. So can you explain why this email is being sent to you? No. Did you do anything

01:35:21 with the information you were sent in this email? Did you do any checks? Not to my knowledge. And the

01:35:29 email states that all technical details are available within the document library. You see

01:35:36 that underneath the bullet point, it says the compliance declaration form and all relevant

01:35:42 technical details of the above are available within the document library. I wanted to know

01:35:47 whether that included the type approval summary. We assumed it would. Can you help us on that?

01:35:52 I wasn't responsible for the document library. I can't answer the question. Now, we can see

01:36:03 from this email, we can see that votes were due from the peer review group by the 4th of July,

01:36:11 2013. Can you see that's in bold towards the top of the email? So the peer review group

01:36:16 being sent this and asked for their votes by the 4th of July, 2013. Now, let's just go back to the

01:36:24 Registered Details Manual and what it says in relation to this peer review process. If we can

01:36:30 go to HBC 6023 and look at page 27. So here, in Appendix 10 to this manual, we have a section

01:36:49 on the peer review process. And it tells us at the top of the page, once the necessary checks

01:36:53 and paperwork has been returned by the research authority, the Registered Detail Application is

01:36:58 added to the LABC website forum for validation by peer review. This stage is crucial to the

01:37:05 entire process of Registered Details because it demonstrates an audit trail to certification

01:37:11 by consideration from independent professionals. Do you see that? Yes. And then it goes on. It

01:37:19 confirms in the next substantive paragraph that all the information received as part of the

01:37:23 application is uploaded into the document library. So it tells us that. And then further down that

01:37:32 paragraph, there's a sentence beginning, they should then review the supporting information

01:37:37 to ensure that it is relevant to the product and demonstrates its suitability.

01:37:42 And it says this after that, it is not necessary to undertake a full check, as this should already

01:37:48 have been done by the research authority. An evidential desktop review is all that is required.

01:37:58 Now, I'm going to come back to that phrase in a moment. And then the beginning of the next

01:38:03 substantive paragraph says, currently four votes are required to certificate the application.

01:38:10 This will be reviewed pending support of the voting system. If there are more members prepared

01:38:16 to peer review within the timescales, then this would demonstrate a more robust system.

01:38:21 Now, from the correspondence and the documents available to the inquiry, we can only see one

01:38:26 response to this peer review process from a man called Tim Bartlett of West Suffolk Council.

01:38:36 Now, he ends up being involved in the RS5000 story. So we'll come back to him with your

01:38:42 colleague, Mr. Ewing. If we go to LABC 305139, we can see his response in the second email down on

01:38:55 page one. On the 26th of June, Mr. Bartlett says, good morning, Cathal. I left a post earlier in

01:39:03 the week in support of registered details 165, call them K15. And then he goes on. Now, that is

01:39:10 the only response we can find to this peer review process. And we haven't seen any others. Can you

01:39:17 help us as to whether four votes were in fact received from the peer reviewers? No, I can't.

01:39:23 I was not part of that process at that time. I'm sorry. I have no idea. Can you help us as to what

01:39:31 would happen if there was a dissenting vote as part of the peer review process?

01:39:35 Yes. The peer review group would then be asked to reconsider as far as I'm aware.

01:39:48 As I said before, this was not part of my day-to-day work. And in fact, with the additional

01:39:55 employment of people within LABC, I became more and more remote from it. So this particular

01:40:04 process was now outside my remit almost. So I can't comment on what happened with this particular.

01:40:18 Can you comment on what was supposed to happen as part of this peer review process? We saw in the

01:40:24 manual that it said it's not necessary to undertake a full check, as this should already have been

01:40:30 done by the research authority. An evidential desktop review is all that's required.

01:40:35 What does that mean? It would be that the

01:40:41 items listed in an approved document were matched with the documents that had been reviewed,

01:40:51 not the content of those documents. I'm not sure I understand that.

01:40:57 So if the approved document requires a certificate for spread of flame, a certificate for

01:41:10 heat generation, a certificate for structural stability, all those are listed.

01:41:20 So they'll simply note that there's a claim about fire performance, note that there's a certificate

01:41:25 that relates to fire performance, and tick that's it, yes?

01:41:29 Pretty much. It was up to the individual giving the response as to how much he wanted to investigate

01:41:39 it. It wasn't necessarily that the certificate was checked. It was just that the certificate

01:41:46 as to how much he wanted to investigate it. It wasn't dictated by LABC as to how they

01:41:54 carried out that work, and some would look at it in more detail than others.

01:41:59 If you're right as to what that process involved, how is that any form of check or verification?

01:42:05 Why isn't it? Why when you check whether a certificate that's listed in an approved

01:42:12 document has been necessary and a product has got that certificate,

01:42:18 why would you need to do anything else? Because you need to check that whatever

01:42:22 statements are made in the LABC certificate are supported by the test information that you've got.

01:42:32 It would be, but the detail of, I mean a BBA certificate for argument's sake can run to

01:42:42 14 or more pages, and it may be, well quite frankly, the most important page is towards

01:42:52 the back of the document, or used to be, I think they put them at the front now. Did it achieve

01:43:00 XYZ? And if that information is there, then that is your peer review.

01:43:08 So are you saying it would be unreasonable to inspect the peer reviewers

01:43:12 to read on beyond the front page of a BBA certificate?

01:43:15 There has to be a degree of belief that your colleagues are capable of doing something,

01:43:23 otherwise you're doing the thing three times over.

01:43:26 Well that of course is true, but how does the peer review operate to eliminate unconscious errors?

01:43:35 We know that the certificate that we've been discussing made certain statements about

01:43:41 combustibility and fitness for use on high-rise buildings. How would anyone to check whether those

01:43:48 statements had been correctly or incorrectly transposed from the underlying documentation?

01:43:55 They would, in as much as if it had been reviewed, but you've already told me that you've found no

01:44:07 evidence to say that there was a peer review on this particular document.

01:44:12 No, no, I'm asking to comment on the system, the system as you've described it.

01:44:18 If there is a statement that was to say a material is a non-combustible material,

01:44:30 then I would expect that that will be indicated on the certificate issued by the testing laboratory,

01:44:38 and that will have been viewed by the peer review process.

01:44:44 This may be what I'm not understanding, it may be my fault. I thought what you were telling us was

01:44:50 that those who were asked to undertake the peer review were expected to satisfy them that supporting

01:44:57 documentation as documents existed, but not to examine the supporting the contents of the

01:45:05 supporting documentation.

01:45:10 Yeah, you may have sort of, perhaps I've not explained myself very well, but the process is

01:45:20 one of an overview of what somebody has done in detail. So if there is a statement, which as we've

01:45:30 already discussed is incorrect, it should have been picked up. The peer review was intended

01:45:39 to cover that process. Now if the peer review has failed in that process,

01:45:45 so be it, I can't answer for it, that is a reality.

01:45:50 So I think it follows that you would expect the peer review process to examine the contents of

01:45:58 the underlying documents to some extent, because that would be how you would pick up the mistake,

01:46:06 isn't it?

01:46:06 It would. A lot would depend on the detail that you were actually examining.

01:46:13 If we're looking at this particular statement, then one would expect that that statement was

01:46:24 found somewhere in the documentation and should have been checked.

01:46:32 I'm struggling to think of an example where you wouldn't need to read everything in

01:46:38 total composite detail, but there will be occasions when

01:46:45 if a statement is not made about, you know, there's a requirement for a product to provide a certain

01:46:55 fire resistance, 30 minutes, 60 minutes. There's a certificate to say that it achieves that,

01:47:05 full stop. There's no statement made to that effect anywhere else. You don't need to check any further

01:47:11 to see how it achieved it. Does it need to be fitted in a certain way?

01:47:18 You expect that to be part of the detailed document.

01:47:21 That I understand. That's very helpful. Thank you very much.

01:47:27 If we move forward with the story now, on the 28th of June 2013, Mr Brennan, if we go to LABC

01:47:34 40925, Mr Brennan sends an email to Gareth Mills of Kingspan.

01:47:42 Telling him that the peer review section, here we have it, the final peer review section of the

01:47:47 registered details process has now been completed for the K15 system. Please find attached draft

01:47:52 copies of your registration certificates. Now, can you help us, and you may not be able to, but

01:47:57 I'm going to ask you nevertheless, can you help us as to why Mr Brennan is telling Mr Mills that

01:48:03 the peer review process has been completed on the 28th of June 2013, when responses were asked from

01:48:10 the peer reviewers prior to the 4th of July 2013? I have absolutely no idea. Should that have

01:48:16 happened? It doesn't sound like it. No, because someone might have come along before the 4th of

01:48:22 July and said, I object, I have a problem with this. Unless, no, not necessarily. If the

01:48:28 requisite number of responses had been received, then it would be reasonable to proceed with it,

01:48:36 and not waiting for the full extent of the time period given. I see. So you send it out to a large

01:48:43 number of peer reviewers, as we saw in that email, quite a large number of people, and you just wait

01:48:49 for four yeses, and once you've got your four yeses, the certificate can be issued. Is that right?

01:48:56 That's what the document says. But what if a peer reviewer needed a bit more time,

01:49:02 hadn't got round to looking at it for another few days, and then looked at the certificate and had

01:49:07 a problem with it? How does the system allow for that? Then I don't manage the system. I don't run it,

01:49:18 so I can only surmise. But the process was, if you've got four agreements, you go ahead. That's the

01:49:28 way the document is written. If somebody has got real concerns over it, and they've gone into it in

01:49:33 so much detail, I would expect them to make that concern known as soon as possible. Even if they

01:49:41 need more time to look at it, hang on a minute, I need to look at this a bit further, you know,

01:49:48 and I'll get back to you. Well, doesn't that... Ms Granger, your point strikes me as sad, except

01:49:54 for this. We don't know, do we, whether by the 28th of June all those on the working group had

01:50:02 not responded? Because if you'd had 100% response by the 28th of June, you could go ahead. True.

01:50:08 We've only seen one response at all. Yeah, quite. I understand that. So, yeah, we don't know. Fair

01:50:15 point. But you keep saying, this wasn't my process, but you are copied in, yes, and you are the senior

01:50:25 person at the LABC with technical knowledge. How could you not take an interest in this peer review

01:50:32 process? Because there was a lot of other work going on, and this was a process. There were now

01:50:38 other technical people involved that were trusted to be aware of that process.

01:50:48 Now, we know then that Kingspan requests some amendments to the draft certificate.

01:50:55 You dealt with that in your witness statement, but I want to look at the email that's received

01:50:59 from Kingspan. This is at LABC 40954.

01:51:12 This is an email from Gareth Mills to Mr Brennan on the 1st of August, and he says,

01:51:18 we had a look over the documents and wondered if we could add some more detail into some of the

01:51:22 sections regards where the product can be used. And then there's a detailed email setting out a

01:51:28 number of points that Mr Mills is asking to be included. And I'm not going to take you through

01:51:34 all of this, but I'm going to highlight a number of points. So at point one, it says the product is

01:51:41 suitable for use with a variety of outer claddings, including rain screens. And then at point three,

01:51:48 it says this, the product can be used on buildings with stories greater than 18 meters from ground

01:51:54 level, provided it is used in combination with suitably non-combustible substrates

01:51:59 and ancillary components. Note BS 8414 testing. Now note there, he doesn't tell you what type of

01:52:06 8414 testing there, whether it's part one or part two, but he wants that statement included,

01:52:12 that bold statement that it can be used on buildings with stories above 18 meters.

01:52:17 And he also asks at the end of the email, point six, just scroll down, we've got two images which

01:52:25 we would like to include within the drawing section if possible, which I'll follow up with shortly.

01:52:30 I'd have the images available to send either by various formats. So he wants these two images.

01:52:37 And we can see from the documents that this is referred on to Mr Jones at Herefordshire

01:52:44 and also to Mr Ewing, David Ewing. Now was Mr Ewing in a technical role at the LABC?

01:52:51 Yes. And would you have expected Mr Ewing to have identified whether these requested amendments

01:52:58 were supported by the technical information available to the LABC at the time? Mr Ewing

01:53:03 would have an ability to do that, yes. Right. Now Mr Ewing doesn't appear to have responded,

01:53:09 and we can ask him about that when he appears before us.

01:53:13 Mr Jones, however, confirms that he was happy with these requested amendments.

01:53:17 We can see that if we go to LABC 40936.

01:53:30 So on the 12th of August 2013, Mr David Jones says, copying in Mr Ewing and Mr, sent it to

01:53:38 Mr Ewing and Mr Brennan. Hello, Cathal. I have no problem with those points being incorporated

01:53:43 as part of this certificate. I think the key ones under items one, three and four are already

01:53:51 covered in the Herefordshire council type approval summary. Now he's right about that. Point three

01:53:57 can be used above 18 metres was covered in the Herefordshire council type approvals summary.

01:54:03 And then he says, but see no problem with those points being reinforced as per Gareth's suggested

01:54:08 wording below. Certainly I can't see there's anything there not backed up by the technical

01:54:13 data underpinning the certificate. Now, can you help us? These additions drafted entirely by

01:54:19 Kingspan never seemed to have been subject to the peer review process. Can you help us as to why

01:54:25 that is the case? No. And what happened subsequently is on the 13th of August, Mr Brennan

01:54:35 informs Mr Mills that the research authority are happy for the text to be altered. And then

01:54:42 the registered detailed certificate is sent to Kingspan on the 28th of August.

01:54:47 That certificate appears if we go to LABC three zeros, one three zeros.

01:55:05 So here it is LABC registered system, the registered detail Kingspan, Coultham, K-15,

01:55:14 Rainscreen board. This is the front piece of the certificate and it's dated the 28th of August,

01:55:22 2013. We see that at the bottom. It's valid until the 28th of August, 2014. So valid for a year.

01:55:28 And on behalf of the LABC, it's signed by you. Do you see that? Yes. Now, did you review this

01:55:34 certificate? No. So even though it has your signature on it, you don't review the technical

01:55:42 content at all? No. Given the concerns that have been highlighted by others in the industry in

01:55:48 relation to the 2009 system type approval certificate for K-15, didn't it occur to you

01:55:54 that it was important to check the certificate that was being signed in your name to make sure

01:55:58 it was accurate? I wasn't aware that it was being signed in my name and I put my trust in those

01:56:04 dealing with the process to have equal technical knowledge on the matter, if not greater technical

01:56:12 knowledge than I did. When you say I wasn't aware that it was being signed in my name,

01:56:17 when did you become aware that certificates like this had your name on them? I was aware that the

01:56:24 certificates were being, or my signature was being used on these documents. I wasn't aware when this

01:56:31 particular one was issued or at the time it was issued. It was just, yes, they go out with my

01:56:37 signature on it at that particular time. Are you asked to authorise the issuing of a certificate?

01:56:45 No, I was not. So someone in the office just puts your signature on it? If I was asked to authorise

01:56:52 it, if you think I should have been, that may be an omission, but the answer is no, I was not.

01:56:57 Thank you. Now if we go to an accompanying document, LABC 301001,

01:57:07 this is the drawings and document list which accompanies the certificate, the LABC registered

01:57:13 details drawing and document list. And we can see in the third box down under supporting documentation

01:57:20 that it's got the Herefordshire Council type approval summary, which we just looked at,

01:57:24 and then it's got the ninth issue of the Kingspan's own marketing material and the 2008 BBA

01:57:32 certificate 084582. Now we take it from this that it was intended that this document would accompany

01:57:44 the main certificate, is that correct? Yes.

01:57:47 And this would be available online and on the LABC website, is that correct? I believe so, yes.

01:57:58 And we know that from the registered details manual, it confirms that the registered details

01:58:03 certificate and the drawing and document list is added to the LABC website, that's what it says

01:58:07 there, is that your understanding? Yes. And then this drawing and document list is added to the

01:58:13 website, is that correct? Yes.

01:58:14 And then this drawing and document list then includes appendix A on page two,

01:58:23 and we can see that appendix A is verbatim exactly what was suggested by Gareth Mills

01:58:30 in his email to the LABC about the additional information that he wanted included, so point one,

01:58:37 product is suitable for use with a variety of outer claddings including rain screens,

01:58:42 point three, the product can be used on buildings with stories greater than 18 metres from ground

01:58:46 level provided it's used in combination with suitably non-combustible substrates and ancillary

01:58:51 components, and it's got a reference to 841 for testing and the requirements of BR135,

01:58:58 and then we can see the inclusion of two diagrams on page three, which are the diagrams that Mr.

01:59:04 Mills asked to be included, K15 with a steel frame and K15 with a terracotta tile. Now we

01:59:13 know at this time that Kingspan had not in fact tested their K15 product with a steel frame system,

01:59:21 they'd only tested one time in 2005 or a successful test with a masonry substrate.

01:59:28 So what we see from this is that the Kingspan suggestions have simply been cut and pasted

01:59:34 into this appendix to the drawings and document list, is that correct?

01:59:39 It would appear so.

01:59:40 And can you explain why the information that's in that that wording is misleading in terms of

01:59:48 K15 and its use above 18 metres?

01:59:51 Can I explain by way of what should have happened or can I explain why it was

02:00:06 done in the way it was on this certificate?

02:00:08 Can you explain why those errors, I mean go back one page, why the bold statement is made at point

02:00:14 three that the product can be used on buildings with stories greater than 18 metres without any

02:00:20 real qualification, why that appears in this as part of this certificate documentation?

02:00:28 Not being party to the document production, I can't explain it, no.

02:00:39 There is an obvious omission purposefully or otherwise with regards to which 841 test,

02:00:46 8414 test is being referred to and I can't explain why because I wasn't party to its production.

02:00:59 I see. Well what it should have said is that K15 can be used in accordance with one system

02:01:05 and one system only and that system ought to have been described, do you accept that?

02:01:09 I do, yes.

02:01:09 Yes.

02:01:11 Now we know that there was just moving forward with the story, there was a revised BBA certificate

02:01:18 issued for K15 on the 17th of December 2013 and we can see that you became aware of this

02:01:25 on the 11th of July 2014 by way of an email from Steve Evans of the NHBC and I want to look at this

02:01:32 carefully. If we go to LABC 40882 and if we go the second email down, this is an email from Steve

02:01:45 Evans of the NHBC, he's the senior area technical manager, we see that from the bottom of the page,

02:01:52 to you and Mr Basson, 11th of July 2014 and he says this, Barry Doug hope that you are both well,

02:02:00 please keep this confidential at this time but felt that you may like to see this approach

02:02:06 we have had from DCLG and my response. I have mentioned this at BCA meetings in the past

02:02:13 but it is now coming to a head. I note that the LABC registered detail expires in August this year

02:02:21 so you may wish to consider this in light of the amended BBA certificate issued in December 2013.

02:02:29 Happy to discuss further regards Steve Evans. So that's what Mr Evans says to you and then what

02:02:35 he's done is he's forwarded below an email chain that he's had with Mr Brian Martin. Now if we look

02:02:42 first at Mr Martin's email at the bottom of page three, this is dated the 2nd of July 2014

02:02:54 and the subject is fire safety facades and he says hi Neil, this is to Neil Smith

02:03:00 NHBC, he says I've been talking to a few folk about fire safety and facades recently.

02:03:07 Allegedly several buildings have been erected where PIR insulation has been used in cladding

02:03:13 panels well over 18 meters in height. Apparently people are under the impression that PIR is a

02:03:20 material of limited combustibility which it isn't. Again allegedly many of these buildings

02:03:26 are blocks of flats. I've no idea how true these allegations are but they come from relatively

02:03:32 reliable sources. The purpose of my email is a friendly warning, you might want to double

02:03:38 check with your inspectors and plan checkers that they are on top of this. Happy to discuss regards

02:03:44 Brian. So that's Mr Martin's email and then Mr Evans has forwarded your response that,

02:03:52 sorry his response to Mr Martin so you can see that too. That's on page two

02:03:59 and it's dated the 11th of July and he says this, dear Brian I hope that you are well,

02:04:06 Neil Smith has discussed your email with me below and asked me to respond as I've been dealing with

02:04:10 this on behalf of NHBC. This is an issue that NHBC are aware of and have been in discussions

02:04:17 with industry about it for some time. The issue is in respect of the use of Kingspan Cool Thim K15

02:04:23 rain screen board in buildings over 18 meters in height. The confusion has arisen from Kingspan's

02:04:29 statement that their product is acceptable for use in a building over 18 meters. However the product

02:04:35 is made from a generic type of polyurethane foam which is by nature combustible. However since 27th

02:04:42 of October 2008 the product held a BBA certificate attached which indicates that it is acceptable

02:04:48 for use in accordance with approved document B volume 2 paragraph 12.7 7.1 subject to advice

02:04:56 being should be sought from the certificate holder 7.2 if the building exceeds 18 meters in height.

02:05:03 It was on this basis that NHBC building control and other building control bodies

02:05:08 accepted the use of K15 in buildings over 18 meters in height including blocks of flats.

02:05:14 We understand that LABC have also issued a registered detail approving the material for

02:05:21 use over 18 meters. Then he goes on, in January of this year we were made aware of a revised

02:05:28 BBA certificate for K15 issued on the 17th of December 2013 also attached. The new certificate

02:05:35 removed the passage which indicate that it was acceptable for use in accordance with approved

02:05:39 document B volume 2 paragraph 12.7 and instead states that the product will not contribute to

02:05:45 the development stages of a fire but that it has only been tested and therefore is only suitable

02:05:51 for one specific construction on masonry walls 8.2. As we had a number of projects under

02:05:58 construction and in advanced stages of design utilizing K15 NHBC approached Kingspan and made

02:06:03 them aware of our concerns. As a result of this dialogue Kingspan are currently undertaking further

02:06:09 testing using different cladding and facade treatments in accordance with BS8414 part 1

02:06:15 2002. The results from the tests are expected by the end of this month and NHBC are meeting

02:06:20 with Kingspan at the beginning of August at which time Kingspan will be asked to provide evidence

02:06:25 that their product can be used in alternative construction types other than that specified in

02:06:29 the current BBA certificate. And then he goes on, there is no reason to suspect that buildings which

02:06:36 have been built with Kingspan K15 are at risk at this time. It is just the fact that the testing

02:06:43 carried out to date does not bear this out. Kingspan are confident that the testing currently underway

02:06:48 will prove the suitability of the material for use over 18 meters. If they are not able to do this

02:06:54 we will begin the process of informing industry that the product is no longer suitable for use

02:06:58 in facades over 18 meters as well as informing other stakeholders such as BCA and the fire and

02:07:04 rescue service although both parties are already aware of our ongoing discussions. I trust that

02:07:10 this addresses your immediate concerns and will keep you informed for the developments. In the

02:07:14 meantime if you have any queries or would like to discuss further please feel free to get in touch.

02:07:19 So that email is sent to you. Do you know why Steve Evans wanted you to keep this email

02:07:29 confidential? It's one of the things that he said. No. What steps did you take upon receiving this

02:07:41 email to ascertain what had happened with LABC certificates and the approval of K15?

02:07:50 I don't recall. I may well have

02:07:58 passed it on to those dealing with registered details but I have no recollection of the actual

02:08:02 action taken. So you don't recall taking any action yourself in relation to these emails? No.

02:08:12 Can you recall considering whether to take some action in response to it?

02:08:22 I recall discussions with various people including Steve Evans over the wording of the

02:08:36 BBA certificates and how it was being used in various aspects of it and I think it was an ongoing

02:08:48 process that may well have not come to a conclusion but as indicated there,

02:08:57 people were awaiting further information. Yes but wouldn't the first thing be to do

02:09:03 on receipt of this quite serious exchange of emails you've seen to go and check what the LABC

02:09:10 have said and have they said it was a material of limited combustibility as reported by Brian Martin?

02:09:18 I can't comment on that because I don't know whether I did or not and I don't know whether

02:09:22 it was brought to the attention of the people dealing with registered details. I do not recall it.

02:09:29 Well we can see at the top of the chain that we'll see it in a moment you do refer this email on

02:09:37 to Mr Ewing and we'll see that in a moment but do you recall discussing it with Mr Ewing or any other

02:09:46 LABC colleagues? I can't recall the detail of any discussion as I've indicated to you

02:09:56 and aware of it you've already told me more than I could remember in the fact that it was passed on

02:10:02 so I can't comment any further. Okay just a few questions about the detail of what's said in here.

02:10:10 Steve Evans mentions that he has previously raised this in BCA meetings.

02:10:17 Can you help us as to what he might have raised? That's the second line in his email at the bottom

02:10:22 of page one. I can only surmise it's a generality of what is laid out in that email.

02:10:33 I don't recall the discussion in any detail whatsoever. It may well have been that there

02:10:41 was a discussion at that point as to the

02:10:48 validity of various aspects of it but I really can't recall.

02:10:55 Did you realise that there was an urgent need to check the LABC registered detail

02:11:02 in the light of what Mr Evans was flagging up to you? You have a record of the actions taken and

02:11:07 that is all that I can refer to as what took place. Yes and we need some help as to what

02:11:18 action was taken I'm afraid and you simply can't help us with that? Is that your position? Yes.

02:11:26 I do not recall the dealings associated with it. I do recall at various times

02:11:36 discussions with BCA, with people within LABC

02:11:48 and as we know things were changed were subsequently changed as time moves on.

02:11:54 Whether those discussions took place at this time or whether they were subsequent

02:12:00 I can't recall a timeline. Right so you can't help us as to whether you were aware in general

02:12:06 of this problem of the use of combustible insulation materials in buildings over 18

02:12:12 metres at this time? Not to the extent that it was considered a major issue and as Steve

02:12:24 Evans has stated there it was not considered at that time to be a problem and we were waiting

02:12:32 for the tests. Yes if we look at the top of page three and what Mr Evans said back to Mr Martin

02:12:40 he says there's no reason to suspect that buildings which have been built with Kingspan K15

02:12:44 are at risk at this time it's just the fact that the testing carried out to date does not bear

02:12:50 this out. Did you agree with that view that there was no reason to suspect that buildings were at risk?

02:12:58 I'm not sure that I considered it in so much detail. Did you discuss that view with Mr Evans?

02:13:11 Not that I recall.

02:13:13 Did you have any concern about the number of buildings that might have been

02:13:18 approved with K15 because of the LABC certificates either the system type approval

02:13:24 or the registered details certificate? Did you have any concerns about that at this point?

02:13:30 Had I flagged it up anywhere you would have a record of it and you don't so the answer to that

02:13:36 must be no I didn't. Can you help us as to why you weren't concerned? No it is

02:13:44 likely that it was played down by all the parties involved including in the emails that you have

02:13:52 there you know the urgency was not flagged up. Was any consideration given

02:14:03 to warning LABC members about this potential problem so that they were at least alive to it

02:14:10 even if you weren't recommending any immediate positive action? Not by me.

02:14:17 And why not not by you given the technical role that you held within LABC? Who else

02:14:22 should have taken that decision? It could have been a number of people within

02:14:28 could have been a number of people within within LABC at that time that were also involved on it

02:14:36 on a technical side of it. Yes you can say it should have been me. It wasn't and it wasn't done.

02:14:45 And again the the whole focus the whole world was looking at thermal performance at that time

02:14:52 and I think the you know

02:15:00 people's eye was taking off the ball because of the push for home improvement and thermal performance

02:15:10 mine included. Yeah I appreciate that that that was the context to this but once you've got

02:15:18 a senior civil servant raising this problem with NHBC and then them raising it with you

02:15:26 wasn't that something pretty serious that needed to be given detailed consideration by LABC?

02:15:36 For whatever reason it would appear it wasn't seen at that in that way at that time.

02:15:42 When you saw the email did you make any connection between Mr Martin's friendly warning and the claims

02:15:51 by Kingspan that K15 was suitable for use over 18 meters? No I didn't join the dots.

02:16:00 And you didn't join the dots to your own certificates the your own LABC certificates

02:16:05 including the one signed by you? The one it had been brought it was brought to the attention

02:16:12 as you've already said to to Mr Ewing and could be looked it was going to be looked at further.

02:16:20 The urgency was not flagged up in that way or not or not recognized.

02:16:29 Did it even occur to you that the LABC certificates might have supported and possibly facilitated

02:16:36 the claims made by Kingspan in respect of suitability for use over 18 meters? No.

02:16:44 Did it occur to you that the inaccurate content of LABC certificates might have at least in part

02:16:49 contributed to or even caused the situation which had led to Mr Martin sending his friendly warning

02:16:56 email? No.

02:17:04 Did you notice that Mr Evans had told Mr Martin in his response that we understand LABC have also

02:17:13 issued a registered detail approving the material for use over 18 meters? Did you notice that that

02:17:18 was being reported back to Mr Martin? Yes. Mr Martin's email is effectively raising

02:17:27 the same concern that Mr Cody raised from Rockwall back in September and October 2009 i.e. K15 is not

02:17:36 a material of limited combustibility. Did you make that connection? No. Why not? I don't know.

02:17:44 So you didn't think back at all to the correspondence you'd had from Rockwall? Obviously not.

02:17:54 Now at this stage July 2014 it's clear that you'd become aware now that there was a revised BBA

02:18:02 certificate in relation to K15. That's correct isn't it? Yes. Now we can see you've sent Steve

02:18:11 Evans's email to David Ewing on the 15th of July 2014. We see that at the top of the page.

02:18:23 Top of page one sorry.

02:18:27 And you say this to Mr Ewing, hi Dave something you may be aware of if not then for your info

02:18:35 Barry. Now first of all why did you send this email to David Ewing at the LABC? Because he was

02:18:43 dealing with registered details. And what steps if any did you expect Mr Ewing to have taken on

02:18:51 receipt of this email? To give it the consideration that you're expecting should have been given.

02:18:58 Yes I mean it's fair to say your email doesn't exactly suggest that this is an important issue

02:19:05 does it or an urgent issue it just says if not then for your info. Yes. So can we take it from

02:19:12 that that you really didn't think that this was a big deal at the time? It would appear so.

02:19:18 So on the 16th of July 2014 a Mr Clive Everett from Europa facade consultants

02:19:30 had sent an email to Mr Brennan expressing concern about the content of the registered

02:19:35 details certificate for K15. Let's just look at that email LABC 40835.

02:19:50 So here we can see Mr Everett's email of Europa facades and he says dear Cathal it was good to

02:19:56 talk to you earlier and discuss this issue with you. The query we have is the LABC registered

02:20:02 details 165 certificate clearly shows in figure one the Kingspan K15 product being used on a

02:20:08 lightweight steel structural framing system an arrangement for which it is often used and for

02:20:14 which it is perfectly suited. However when we start to look at buildings that are above 18 meters high

02:20:20 in accordance with approved document B we need to ensure that the insulation is either non-combustible

02:20:25 or that the system not just the insulation has been tested to BS 8414 part two.

02:20:33 Now pausing there did you know that at the time that for buildings over 18 meters

02:20:39 the insulation in fact he's got it wrong it's not that it's non-combustible it needs to be of limited

02:20:43 combustibility or that the system not just the insulation has been tested to BS 8414. Did you

02:20:50 know that at the time? That it had to be tested. That either it had to be of limited combustibility

02:20:56 or it had to have been tested as part of a full system test and only the system used. Did you know

02:21:01 that? I was aware of what was in the approved document in terms of recommendations it's not

02:21:09 something that I read on a day-to-day basis but yes I was aware that systems and I was aware of

02:21:17 the the BS 8414 tests. Right he goes on he says the LABC registered detail certificate indicates

02:21:26 that the K15 is suitable for buildings over 18 meters high and substantiates this by referring to

02:21:31 and then he quotes from a particular Kings band publication and the BBA certificate from 2008 a

02:21:37 copy of this certificate is attached. Section 7.2 states in buildings with a floor above 18 meters

02:21:44 advice should be sought from the certificate holder. Section 7.5 refers to the K15 product

02:21:50 having been tested in accordance with BS 8414 part one for non-load bearing masonry substrates.

02:21:57 Our point being that nowhere in the BBA certificate does it confirm that K15 has been

02:22:01 tested in accordance with the requirements of 8414 part two which is for non-load bearing

02:22:06 lightweight structures and then he goes on the current BBA certificate in section 8.2 again refers

02:22:14 only to 8414 part one masonry substrate testing. It also states that the following cutting

02:22:21 construction met with the criteria as stated in the BRE report and then goes on to describe

02:22:26 a construction that has the insulation mechanically fixed to a non-combustible substrate etc.

02:22:34 And then he goes on

02:22:38 we go over the page

02:22:42 fully understanding that this is a complex issue can the LABC confirm whether they have some evidence

02:22:47 that's not been discussed here that shows that the Kings band K15 product meets the requirements

02:22:51 of 8414 part two we've asked Kings band this question previously and at the time of our last

02:22:57 communication with them April this year Kings band confirmed that the K15 insulation product

02:23:02 had not been tested in accordance with BS 8414 part two as a further note we've had a number

02:23:08 of discussions with the BRE regarding this and the 8414 part two test the BRE's view is that the

02:23:14 test is system specific and not product specific it is the system that is being tested to ensure

02:23:20 it remains stable and the mode of mechanical failure of the system is considered as part of

02:23:24 the test the BRE have advised as if an insulation product works in one system I meets the requirements

02:23:31 of br 135 and passes the 8414 part two test while it may be an indicator that the same insulation

02:23:37 will work on another system it does not confer an automatic compliance compliance can only be

02:23:42 achieved through test to this end it seems that stating that an insulation product compliant with

02:23:47 BRE 135 is not possible other than in a particular tested configuration assembly we would be

02:23:54 interested in your thoughts on the subject particularly as we've just been issued with

02:23:57 the registered details 165 certificate by a specialist contractor for a project on the

02:24:03 understanding on their part that this can be used as proof of compliance with adb and br 135

02:24:09 we look forward to hearing from you

02:24:13 now did anyone at the labc can you help us ever respond to mr everett's email did you ever see it

02:24:22 I don't recall ever seeing that no can you explain why that wouldn't have been sent to you

02:24:30 as the senior technical person within the labc because it was sent to the people dealing with

02:24:36 the registered details but it's clearly I mean he says at the top of that page it's a complex

02:24:41 issue why wouldn't they refer it on to you and get your views on it you have to ask them I don't know

02:24:55 now mr ewing was responsible for the registered details scheme is that right

02:25:00 was that your understanding at the time yes one of the people responsible for it

02:25:11 so would you have expected him to have responded to this email

02:25:17 or sorry to have been referred this email either either him or mr taylor martin taylor

02:25:27 both with

02:25:31 equal sort of standing in technical ability to myself

02:25:39 I see but you can't help us as to why we can't see that happening nor can we see

02:25:44 any response to mr everett's email I have not seen this previously so I can't answer your question

02:25:52 answer your question okay mr chairman I think that is a good moment to stop I'm making

02:26:00 good progress and I should be hopefully done with this witness sometime in the morning

02:26:06 tomorrow so that we can then start mr ewing before the lunch break right well um there we are mr

02:26:13 tenor that's obviously a convenient point to stop for the afternoon I'm afraid we're going to have

02:26:17 to ask you to come back there's some more questions tomorrow morning but at least it sounds as though

02:26:22 you should be able to get away before lunch which I hope will is your arrangements thank you and

02:26:29 again I just have to remind you not to talk to anyone about your evidence over the break

02:26:33 and we'll see you at 10 o'clock tomorrow morning okay all right thank you very much

02:26:52 thank you very much miss grange 10 o'clock tomorrow then please okay